「Epi practicals - 12 April 2021」の版間の差分
ナビゲーションに移動
検索に移動
Vaccipedia.admin (トーク | 投稿記録) |
Vaccipedia.admin (トーク | 投稿記録) |
||
1行目: | 1行目: | ||
− | == | + | ==12 April 2021== |
− | === | + | ===Is this test useful: Practical - HIV=== |
− | Is this test useful | ||
− | |||
− | Practical - HIV | ||
*Q1 | *Q1 | ||
82行目: | 79行目: | ||
*Q6 | *Q6 | ||
We should advise the director that donors should be informed to proceed to an additional confirmation test, not just be informed simple positive result. | We should advise the director that donors should be informed to proceed to an additional confirmation test, not just be informed simple positive result. | ||
+ | |||
+ | ===Is this test useful: COVID-19 Practical=== | ||
+ | *Question 1 | ||
+ | {|class="wikitable" | ||
+ | |- | ||
+ | ! | ||
+ | !RT-PCR Positive | ||
+ | !RT-PCR Negative | ||
+ | |- | ||
+ | !IgG/M RDT Positive | ||
+ | |91 | ||
+ | |6 | ||
+ | |- | ||
+ | !IgG/M RDT Negative | ||
+ | |7 | ||
+ | |174 | ||
+ | |- | ||
+ | !sum | ||
+ | |98 | ||
+ | |180 | ||
+ | |} | ||
+ | *Sensitivity=<math>\frac{91}{98} = 92.9\%</math> | ||
+ | *Specificity=<math>\frac{174}{180} = 96.7\%</math> | ||
+ | |||
+ | *Question 2 |
2021年4月12日 (月) 16:19時点における版
12 April 2021
Is this test useful: Practical - HIV
- Q1
With disease | Without disease | |
---|---|---|
test positive | 152 | 20 |
test negative | 8 | 980 |
- Q2
- Sensitivity=[math]\displaystyle{ \frac{152}{160} = 0.95 }[/math]
- Specificity=[math]\displaystyle{ \frac{980}{1000} = 0.98 }[/math]
- Q3
a)
With disease | Without disease | sum | |
---|---|---|---|
test positive | 38 | 1999.2 | 2037.2 |
test negative | 2 | 97960.8 | 97962.8 |
sum | 40 | 99,960 | 100,000 |
- Positive predictive value=[math]\displaystyle{ \frac{38}{38+1999.2}=0.0187 }[/math]
- Negative predictive value=[math]\displaystyle{ \frac{97960.8}{2+97960.8}=0.999 }[/math]
b)
With disease | Without disease | |
---|---|---|
test positive | 316.35 | 13.34 |
test negative | 16.65 | 653.66 |
sum | 333 | 667 |
- Positive predictive value=[math]\displaystyle{ \frac{316.35}{316.35+13.34}=0.959 }[/math]
- Negative predictive value=[math]\displaystyle{ \frac{653.66}{16.65+653.66}=0.975 }[/math]
- Q4
To have high sensitivity is more important, because testing blood donor is a screening test and false-negative has to be excluded as much as possible.
- Q5
We need to calculate PPV and show the director how much false-positive donors arise.
- Q6
We should advise the director that donors should be informed to proceed to an additional confirmation test, not just be informed simple positive result.
Is this test useful: COVID-19 Practical
- Question 1
RT-PCR Positive | RT-PCR Negative | |
---|---|---|
IgG/M RDT Positive | 91 | 6 |
IgG/M RDT Negative | 7 | 174 |
sum | 98 | 180 |
- Sensitivity=[math]\displaystyle{ \frac{91}{98} = 92.9\% }[/math]
- Specificity=[math]\displaystyle{ \frac{174}{180} = 96.7\% }[/math]
- Question 2